TSI 4140 and 4040

Hover to zoom

TSI thermal mass flowmeters include a proprietary platinum film sensor design for measuring gas flows in applications demanding fast response and high accuracy over a wide flow range. These models have various features for example a 4 millisecond flow response, high accuracy ± 2 % of reading and low pressure drop including many others. The TSI 4000 / 4100 series was designed specifically for ultra-low pressure loss to minimize any desireable effects the flowmeter can have on the readings under testings. 

Product Features

  • 2 model types
  • Document downloads

Instrument product options

1. Select a model (2 available)


 
Quantity
Continue to select accessories

2. Select accessories

3. Select a calibration

Overview

Features

  • 4 millisecond flow response
  • High accuracy ± 2 % of reading
  • High turndown ratio
  • Low pressure drop
  • Convenient analog output of flow rate
  • Versatile digital output of flow rate, volume, pressure, temperature
  • Built-in temperature and pressure compensation
  • NIST-traceable calibration certificate included at no additional cost
  • RS232 Interface for digital outputs and configurable device options
  • Set analog output zero and scaling
  • Specify start/stop trigger levels for volume measurement
  • Set update rate for LCD display
  • Set sampling rate for analog and digital outputs
  • Select gas calibration
  • Select either standard or volumetric flow measurement
  • Set display units for model 4140 to L/min or cm3/min
  • Compute volume

Technical

For full technical details, please see the data sheet.

MODEL 4140

Gas calibration      Air, O2, N2

Inlet/outlet diameter      0.25 ” (6.4 mm)

Range      0.01 - 20 Std L/min

Accuracy — Air and O2      ± 2 % of reading or 0.005 Std L/min, whichever is greater

Accuracy — N2      ± 3 % of reading or 0.010 Std L/min, whichever is greater

Response      4 ms to 63 % of full scale flow

LCD display units      L/min, Std L/min, cm3/min, Std cm3/min

MODEL 4040

Gas calibration      Air, O2, N2, Air/O2 Mixture

Inlet/outlet diameter      22 mm ISO tapered

Range      0 - 300 Std L/min

Accuracy — Air and O2      ± 2 % of reading or 0.05 Std L/min, whichever is greater

Accuracy — N2      ± 3 % of reading or 0.1 Std L/min, whichever is greater

Accuracy — Air and O2 mixture      ± 3 % of reading or 0.1 Std L/min, whichever is greater

Response      4 ms to 63 % of full scale flow

LCD display units      L/min, Std L/min

Downloads

PDF

TSI mass flow 4140 and 4040 data sheet

  • Technical Document
  • PDF file
  • 1 MB
Download