Hydronic Systems Design Set of 2 guides (HSD2)

Features

Set contains Selection of Control Valves for Variable Flow Systems (BG 51/2014) and Energy Efficient Pumping Systems (BG 12/2011). These guides will help designers select the correct control valves and will assis with design of energy efficient pumping systems. 

See full description

Publication format options

    • Hard copy
    • £30.00
    • £30.00
    • £60.00
    • Digital download
    • Free
    • Free
    • £60.00

Full description

Set contains Selection of Control Valves for Variable Flow Systems (BG 51/2014) and Energy Efficient Pumping Systems (BG 12/2011).

Selection of Control Valves in Variable Flow Systems (BG 51/2014) has been produced to help designers avoid problems with the selection and application of control valves used in hydronic systems. Types of valve covered by the guide include two-port, three-port, four-port and pressure independent control valves. Proper sizing of control valves is vital to ensure:

  • Comfort Control – to ensure the heating outputs are properly regulated to meet the requirements of the application and thereby avoiding excessive temperature variations in the controlled media.
     
  • Control of system temperature differential – to maximise the energy efficiencies of low carbon heating and cooling sources by achieving and maintaining the required system temperature deferential under all operating conditions

Energy Efficient Pumping Systems (BG 12/2011) provides recommendations for building services designers on the design of energy efficient pumping systems. However it will be invaluable to a broader group including manufacturers, contractors and end-users who will benefit from being able to design, install, select and manage more efficient systems.

The guide recognises that the potential for pump energy savings is substantial. Europump (a pan European association of pump manufacturers) estimate that systems could be 30 to 50% more energy efficient by careful consideration of components, design and installation. Indeed our research has shown that a potential energy saving of 80% is achievable between the worst operating constant flow systems and the best designed variable flow systems.

Please note we expect delivery of hard copies of BG 51/2014 approximately 4th July so there may be a short delay before despatch. 